(10) No user shall use or allow
the use of any lifting tackle unless the following conditions are complied with,
namely that -
(a) every item of lifting tackle is well constructed of sound material, is
strong enough and is free from patent defects and is in general constructed in
accordance with a generally accepted technical standard;
(b) every lifting assembly consisting of different items of lifting tackle
is conspicuously and clearly marked with identification particulars and the
maximum mass load which it is designed to lift with safety;
(c) ropes or chains have a factor of safety with respect to the maximum
mass load they are designed to lift with safety of
(i) ten for natural-fibre ropes;
(ii) six for man-made fibre ropes or woven webbing;
(iii) six for steel-wire ropes except for double part spliced endless
sling legs and double part endless grommet sling legs made from steel-wire rope,
in which the factor of safety shall be at least eight;
(iv) five for steel chains; and
(v) four for high-tensile or alloy steel chains:
Provided that when the load is equally shared by two or more ropes or
chains the factor of safety may be calculated in accordance with the sum of the
breaking strengths taking into consideration the angle of loading;
(d) steel-wire ropes are discarded and not used again for lifting purposes
if the rope shows signs of excessive wear, too many broken wires, corrosion or
other defects that have made its use in any way dangerous;
(e) such lifting tackle is examined at intervals not exceeding three
months by a person contemplated in subregulation (5) who shall enter and sign
the result of each such inspection in a book kept for this purpose; and
(f) such lifting tackle is stored or protected so as to prevent damage or
deterioration when not in use.